With display False Voltage type for actuating AC/DC Rated operating voltage Ue 200 V Rated control supply voltage at AC 50 Hz 24 V Rated control supply voltage at AC 60 Hz 24 V Overload current 3 A Controller type SMC-3 DV/DT protection 1000V/µs for power circuit Repetitive peak voltage 1600V per UL/CSA/NEMA for power circuit Operating frequency 50/60 Hz per UL/CSA/NEMA for power circuit Line connected motor power | |
---|---|
max 5.5 kW @ 500V AC @ 50Hz | |
3-phase Delta connected motor power | |
max 3...7.5 kW @ 500V AC @ 50Hz | |
3-phase Overvoltage category III per IEC for side mount auxiliary contacts Rated impulse voltage 6 kV for power circuit Dielectric withstand 2500V AC per IEC for power circuit Line connected motor current 3...9A @ 500/575V AC | |
3-phase Delta connected motor current 5.1...16A @ 500/575V AC | |
3-phase Insulation voltage Rated 600V AC per UL/CSA/NEMA for power circuit Rated operational voltage 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts Rated control power during start with fan 215mA @ 120V AC/180mA @ 240V AC | |
800mA @ 24V DC/660mA @ 24V AC Input OFF-state current <10 mA | |
<12 mA @ input off-state voltage (IN1 | |
IN2) for control circuit Short-circuit protection device list Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L Number of contacts TB-97 | |
-98 (OVLD/Fault) | 1 for auxiliary contacts High capacity available fault current |
max 69kA @ 600V | |
maximum current 30 A time delay Class J or Class L fuse for inside delta connected motors Type of current TB-97 | |
-98 (OVLD/Fault) | AC/DC for auxiliary contacts Conventional thermal current (Ith) TB-97 |
-98 (OVLD/Fault) | 1 A for auxiliary contacts Type of control circuit TB-97 |
-98 (OVLD/Fault) | Electromagnetic relay for auxiliary contacts Type of contacts TB-97 |
-98 (OVLD/Fault) | Normally Open (N.O.) for auxiliary contacts Utilization category TB-23 |
-24 (normal/up-to-speed) | |
TB-33 | |
-34 (normal/up-to-speed) | C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts Rated operational current |
max TB-97 | |
-98 (OVLD/Fault) | 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts Standard controller feature Soft stop Standard available fault current |
max 5 kA @ maximum standard fuse 60 A for delta device opsal current rating Rated control supply voltage at DC 24 V Integrated motor overload protection True Short circuit protection device performance (SCPD) type Type 1 Selectable overload trip class Trip Class 10 | |
15 | |
or 20 Selectable start times 2 | |
5 | |
10 | |
15 | |
20 | |
25 | |
or 30 s Input OFF-state voltage (IN1 | |
IN2) | |
max 40V AC @ 17V DC/12V AC for control circuit Selectable current limit 150% | |
250% | |
350% | |
and 450% of full load current Input ON-state voltage | |
during start (IN1 | |
IN2) 85V AC @ 19.2V DC/19.2V AC minimum for control circuit Rated control power during start without fan 205mA @ 120V AC/145mA @ 240V AC | |
705mA @ 24V DC/580mA @ 24V AC Input ON-state current (IN1 | |
IN2) 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit | |
7.3mA @ 24V AC/DC for control circuit |
SMC-3 9A Smart Motor Controller
65% OFF
M2BAX280SA6 ABB MOTOR
(0 Reviews)
$866100$303135
65% OFF
1LE7503-1CA03-5AA4
(0 Reviews)
$104720$36652
60% OFF
KM2BAX71MB4 ABB MOTOR
(0 Reviews)
$21500$8600
45% OFF
ALLEN BRADLEY 1756-L81EXTS
(0 Reviews)
$3545780$1950179
40% OFF
6ES7223-1BH30-0XB0
(0 Reviews)
$28487$17092
40% OFF
6FC5203-0AD10-0AA0 SEIMENS CONTROL PANEL
(0 Reviews)
$1227$736
50% OFF
3WT8326-6UA34-5AB2
(0 Reviews)
$1234920$617460
40% OFF
20GEG4E1K5MNDNNNNN-P50 ALLEN-BRADELY DRIVE
(0 Reviews)
$282866920$169720152
20% OFF
6FX2001-5WD13-0AA0 SIEMENS DRIVES
(0 Reviews)
$174855$139884
20% OFF
FR-HEL-H90K MITSHUBISHI DC Reactor
(0 Reviews)
$150240$120192