150-C9NBR ALLEN-BRADLEY Smart Motor Controller)

In Stock

15 Products Left

$265026

$212020

20% OFF

1

Description Specification Reviews
     

0%

    0
     

0%

    0
     

0%

    0
     

0%

    0
     

0%

    0

Write Review


NO REVIEWS YET!

With display False Voltage type for actuating AC/DC Rated operating voltage Ue 200 V Rated control supply voltage at AC 50 Hz 24 V Rated control supply voltage at AC 60 Hz 24 V Overload current 3 A Controller type SMC-3 DV/DT protection 1000V/µs for power circuit Repetitive peak voltage 1400V per UL/CSA/NEMA for power circuit Operating frequency 50/60 Hz per UL/CSA/NEMA for power circuit Line connected motor power
max 4 kW @ 380/400/415V AC @ 50Hz
3-phase Delta connected motor power
max 2.2...7.5 kW @ 380/400/415V AC @ 50Hz
3-phase Overvoltage category III per IEC for side mount auxiliary contacts Rated impulse voltage 6 kV for power circuit Dielectric withstand 2500V AC per IEC for power circuit Line connected motor current 3...9A @ 380/400/415/460V AC
3-phase Delta connected motor current 5.1...16A @ 380/400/415/460V AC
3-phase Insulation voltage Rated 600V AC per UL/CSA/NEMA for power circuit Rated operational voltage 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts Rated control power during start with fan 215mA @ 120V AC/180mA @ 240V AC
800mA @ 24V DC/660mA @ 24V AC Input OFF-state current <10 mA
<12 mA @ input OFF-state voltage (IN1
IN2) for control circuit Short-circuit protection device list Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L Number of contacts TB-97
-98 (OVLD/Fault) 1 for auxiliary contacts High capacity available fault current
max 69kA @ 600V
maximum current 30 A time delay Class J or Class L fuse for inside delta connected motors Type of current TB-97
-98 (OVLD/Fault) AC/DC for auxiliary contacts Conventional thermal current (Ith) TB-97
-98 (OVLD/Fault) 1 A for auxiliary contacts Type of control circuit TB-97
-98 (OVLD/Fault) Electromagnetic relay for auxiliary contacts Type of contacts TB-97
-98 (OVLD/Fault) Normally Open (N.O.) for auxiliary contacts Utilization category TB-23
-24 (normal/up-to-speed)
TB-33
-34 (normal/up-to-speed) C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts Rated operational current
max TB-97
-98 (OVLD/Fault) 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts Standard controller feature Soft stop Standard available fault current
max 5 kA @ maximum standard fuse 60 A for delta device opsal current rating Rated control supply voltage at DC 24 V Integrated motor overload protection True Short circuit protection device performance (SCPD) type Type 1 Selectable overload trip class Trip Class 10
15
or 20 Selectable start times 2
5
10
15
20
25
or 30 s Input OFF-state voltage (IN1
IN2)
max 40V AC @ 17V DC/12V AC for control circuit Selectable current limit 150%
250%
350%
and 450% of full load current Input ON-state voltage
during start (IN1
IN2) 85V AC @ 19.2V DC/19.2V AC minimum for control circuit Rated control power during start without fan 205mA @ 120V AC/145mA @ 240V AC
705mA @ 24V DC/580mA @ 24V AC Input ON-state current (IN1
IN2) 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit
7.3mA @ 24V AC/DC for control circuit

SMC-3 9A Smart Motor Controller