140M-C2E-B25 ALLEN-BRADELY Motor Protection Circuit-Breaker

In Stock

15 Products Left

$41169

$32935

20% OFF

1

Description Specification Reviews
     

0%

    0
     

0%

    0
     

0%

    0
     

0%

    0
     

0%

    0

Write Review


NO REVIEWS YET!

With integrated auxiliary switch False With integrated under voltage release False Rated short-circuit breaking capacity lcu at 400 V
AC 100 kA Rated operation power at AC-3
400 V 0.75 kw Rated operation power at AC-3
230 V 0.37 kw Rated operating voltage 230 A Type of control element Turn button Overload release current setting 1.6 A Type of electrical connection of main circuit Screw connection Magnetic release current per IEC 33 A Rated operational current (Ie) per IEC 2.5 A Magnetic trip current 33 A Short circuit current (Type 2 coordination)
max-inv 50kA @ 480V Current range 1.6...2.5 A Ultimate short circuit breaking capacity (Icu) per IEC 6kA @ 690V Rated service short circuit breaking capacity (Ics) per IEC 6kA @ 690V Hp rating
max 2Hp @ 575V
3-phase Rated operating voltage
max 690V per IEC
SEV
VDE0660 Electrical life cycle (Ie max.) 100000 ops Short circuit current for combination motor controller with 100-K contactor
max-inv 65 kA @ 480Y/277V
UL 508-Type F Short circuit current for combination motor controller with 100-C contactor
max-inv 65 kA @ 480Y/277V
UL 508-Type F Short circuit current for self-protected combination motor controller with 100-C contactor
max-inv 65 kA @ 480Y/277V
UL 508-Type E Switching of standard motors per IEC 1.8 kW @ 690V
3-phase KW rating
max 1.8 kW @ 690V (AC-3)
3-phase Back up fuse (gG
gL) current rating (if Icc ? Icu ) per IEC No back-up fuse required @ 500V Short circuit current for group motor installation with 100-K contactor
max-inv 65kA @ 480V
UL 508-manual motor controller Short circuit current for motor disconnect with 100-K contactor
max-inv 65kA @ 480V
UL 508-manual motor controller Short circuit current for group motor installation with 100-C contactor
max-inv 65kA @ 480V
UL 508-manual motor controller Short circuit current for motor disconnect with 100-C contactor
max-inv 65kA @ 480V
UL 508-manual motor controller Rated thermal current 0.1...32A @ 60°C ambient temperature (Ith)-inv Short circuit current for tap conductor protection
max 65 kA @ 480Y/277V per UL 508-manual motor controller Short circuit current for combination motor controller
max 65kA @ 480V/277V per UL 508-self-protected (Type E) Fuse or circuit breaker per NEC
max 450 A
UL 508-manual motor controller Fuse or circuit breaker rating per NEC
max 450 A
UL 508-manual motor controller with 100-C contactor Short circuit current for group motor installation
max 65kA @ 480V
UL 508-manual motor controller Short circuit current for motor disconnect
max 65kA @ 480V
UL 508-manual motor controller Magnetic release current Fixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges
(±20 %) Number of poles 3 With thermal protection True Phase failure sensitive True Switch off technique Thermomagnetic Switching frequency
max 25 ops/h Trip class 10 Rated frequency 50/60 Hz Rated supply current 0.1 A Total power loss (Pv) for circuit breaker at rated load operating temperature-inv 6 W Phase loss protection Differential release Fuse or circuit breaker rating with 100-K contactor per NEC
max 450 A
UL 508-manual motor controller Main circuits/overvoltage category 6kV/III @ rated impulse withstand voltage (Uimp) Auxiliary circuits/overvoltage category-inv 6kV/III @ rated impulse withstand voltage (Uimp)

Motor Protection Circuit-Breaker