Device short name ATV212 Product destination Asynchronous motors Network number of phases 3 phases Motor power kW 7.5 kW Motor power hp 10 hp Supply voltage limits 323…528 V Supply frequency 50...60 Hz - 5...5 % Line current 11.7 A at 480 V 14.7 A at 380 V Range of product Altivar 212 Product or component type Variable speed drive Product specific application Pumps and fans in HVAC Communication port protocol APOGEE FLN LonWorks BACnet METASYS N2 Modbus [Us] rated supply voltage 380...480 V - 15...10 % EMC filter Class C2 EMC filter integrated IP degree of protection IP21 Complementary Apparent power 12.2 kVA at 380 V Continuous output current 16 A at 380 V 16 A at 460 V Maximum transient current 17.6 A for 60 s Speed drive output frequency 0.5…200 Hz Speed range 1…10 Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn Local signalling 1 LED (red) for DC bus energized Output voltage <= power supply voltage Isolation Electrical between power and control Type of cable Without mounting kit 1 wire(s)IEC cable at 45 °C
copper 90 °C / XLPE/EPR Without mounting kit 1 wire(s)IEC cable at 45 °C
copper 70 °C / PVC With UL Type 1 kit 3 wire(s)UL 508 cable at 40 °C
copper 75 °C / PVC Electrical connection VIA
VIB
FM
FLA
FLB
FLC
RY
RC
F
R
RES terminal 2.5 mm² / AWG 14 L1/R
L2/S
L3/T terminal 16 mm² / AWG 6 Tightening torque 0.6 N.m (VIA
VIB
FM
FLA
FLB
FLC
RY
RC
F
R
RES) 2.5 N.m
22 lb.in (L1/R
L2/S
L3/T) Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %
<10 A
protection type overload and short-circuit protection Internal supply
<200 A
protection type overload and short-circuit protection Sampling duration 2 ms +/- 0.5 ms F discrete 2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog Response time FM 2 ms
tolerance +/- 0.5 ms for analog output(s) FLA
FLC 7 ms
tolerance +/- 0.5 ms for discrete output(s) FLB
FLC 7 ms
tolerance +/- 0.5 ms for discrete output(s) RY
RC 7 ms
tolerance +/- 0.5 ms for discrete output(s) Accuracy +/- 0.6 % (VIA) for a temperature variation 60 °C +/- 0.6 % (VIB) for a temperature variation 60 °C +/- 1 % (FM) for a temperature variation 60 °C Linearity error VIA +/- 0.15 % of maximum value for input VIB
impedance 7620 Ohm
resolution 10 bits FM switch-configurable current 0...20 mA
impedance 970 Ohm
resolution 10 bits Discrete output type Configurable relay logic (FLA
FLC) NO - 100000 cycles Configurable relay logic (FLB
FLC) NC - 100000 cycles Configurable relay logic (RY
RC) NO - 100000 cycles Minimum switching current 3 mA at 24 V DC for configurable relay logic Maximum switching current 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL
R) 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL
R) 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL
R) 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL
R) Discrete input type F programmable 24 V DC
with level 1 PLC
impedance 4700 Ohm R programmable 24 V DC
with level 1 PLC
impedance 4700 Ohm RES programmable 24 V DC
with level 1 PLC
impedance 4700 Ohm Discrete input logic Positive logic (source) (F
R
RES)
<= 5 V (state 0)
>= 11 V (state 1) Negative logic (sink) (F
R
RES)
>= 16 V (state 0)
<= 10 V (state 1) Dielectric strength 3535 V DC between earth and power terminals 5092 V DC between control and power terminals Insulation resistance >= 1 mOhm 500 V DC for 1 minute Frequency resolution Display unit 0.1 Hz Analog input
impedance 30000 Ohm
resolution 10 bits VIB configurable voltage 0...10 V DC 24 V max
impedance 30000 Ohm
resolution 10 bits VIB configurable PTC probe 0...6 probes
impedance 1500 Ohm VIA switch-configurable current
impedance 250 Ohm
resolution 10 bits Analogue output number 1 Physical interface 2-wire RS 485 Connector type 1 open style 1 RJ45 Transmission rate 9600 bps or 19200 bps Transmission frame RTU Number of addresses 1…247 Data format 8 bits
1 stop
odd even or no configurable parity Type of polarization No impedance Asynchronous motor control profile Voltage/frequency ratio - Energy Saving
quadratic U/f Voltage/frequency ratio
automatic IR compensation (U/f + automatic Uo) Flux vector control without sensor
standard Voltage/frequency ratio
5 points Voltage/frequency ratio
2 points Torque accuracy +/- 15 % Transient overtorque 120 % of nominal motor torque +/- 10 % for 60 s Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 3200 s Automatic based on the load Motor slip compensation Not available in voltage/frequency ratio motor control Automatic whatever the load Adjustable Switching frequency 6...16 kHz adjustable 12...16 kHz with derating factor Nominal switching frequency 12 kHz Braking to standstill By DC injection Network frequency 47.5...63 Hz Prospective line Isc 22 kA Protection type Overheating protection drive Thermal power stage

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 7.5kW / 10hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 6.45kg and its dimensions are, 180mm wide, 232mm high, 170mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet. It is eco-friendly and complies with directives such as RoHS, WEEE, etc.relating to environmental protection.